FAQ
 FAQ
|
|
Q. How to Select the Hose?
- Application - Mild/seldom Use, Regular Use, Tough Use.
- Hose Life Should Be Long.
- Hose Does Not Absorb Water, Needs No Drying After Use
- Hose to Be Resistant of Oils, Acids, Alkalies, Ozone.
- Hose to Be Resistant to Delamination.
- By Number of Layers I.e. Single, Two, Three, or Four Layer Hose
- Suitable to Be Used with Polluted/service Water.
Q. What is the Correct Method of Binding?
- Double Binding
- First with Galvanized Iron ( G.I. ) and Then Second Binding with Copper.
Q. Can the Hose and End Fitings Be Available Together?
- Yes, We are the Only Company in India to Manufacture Hose and Couplings Under One Roof.
Q. Does the Fitting for Hydrants and Accessories Available in Gun Metal Only?
- No We have the Range to Supply in Aluminium Alloy(light Material) and Stainless Steel (pilferage Proof)
Q. What is the Solution to Stop the Theft of Female Coupling of Hydrant Valve?
- We have Gun Metal Landing Valve with Integral Outlet
to Avoid Pilferage of Female Coupling.
Q. Are Branch Pipe and Nozzles Same or Different?
Branch Pipe and Nozzles are Basically Same But Available in Wide Varieties Ranging From
- Straight Jet
- Jet/spray & Shut Off
- Jet, Fog & Shut Off
- Revolving Branch Pipe for Cooling
- Light Weight Polyamide Material German Patterns with and Without Curtain
- No Back Pressure Neulite Nozzle
- Switch Over, Low to High Pressure and Vice Versa Fast Action Nozzle.
Q. with What Maximum Expansion Foam Equipments are Available?
- We have Froam Equipments for Localized Applications and Foam Flooding Applications with Expansion Ratio 1: 3 to 4 to 1000 Times.
Q. What is Difference Between Fire Proximity and Fire Entry Suits?
- Fire Proximity Helps in Fighting Fire At a Certain Distance from Fire Whereas Fire Entry Suit is the Actual Flame Entry.
Q. What is Low Temperature Suit?
- Lpg is Chemical Having Temperature of - 400 C and Low Temperature Suits Enables Person to Work Wearing this Suit in Lpg Plants
Q. What is the Application of Water Monitors/foam Monitors? Is Water Canon Same as Monitor or Different?
- Water or Water/foam Monitors Helps in Fighting Fires from a Long Distance.
- Available in Jet and Jet/spray Type Nozzles.
- Available in Water, Water-foam, Water-foam-dcp all in One Models.
- Available Output from 1750 Lpm to 10000 Lpm.
- Available Throw Horizontal Max. upto 110 Meters.
- Available Throw Vertical Max upto 80 Meters.
- Higher Capacity Monitor are also Called as Canons.
Q. Is Oscillating and Remote Controlled Monitor Same?
- No Oscillating Monitor Oscillates in Horizontal Direction Through Self Powered Oscilating Mechanism.
- Application is for Cooling Purpose.
- Remote Controlled Monitor is the Monitor Fitted in the Risk are ( Tank Farm ) and Its Operation Remotely Controllled from a Safe Area By a Joystick Control Panel.
Q. What is Fire Pack?
- Fire Pack is Self Contained Fire Detection and Extinguishing System Ae3sthetically Designed for Computer Rooms, Server Rooms, and Executive.s Cabin.
Q. Which Fm 200 are You Dealing With?
- We have Great Cakes Fm200 Ub Stock.
- Technical Tie Up with Fire Corporation (usa)
- Trained Engineers By Fike for Designing of the System.
|
| |
|